A completely new range to make Wall Units easier to use. Both faces of the unit are vertical and there are only two thicknesses of wall for the complete range.
| Height | Approx. Weight (t) | Width (m) |
|---|---|---|
| 1.0 | 0.47 | 1.0 |
| 1.5 | 0.62 | 1.0 |
| 2.0 | 1.35 | 1.0 |
| 2.5 | 1.81 | 1.0 |
| 3.0 | 2.04 | 1.0 |
| Size | a | b | c | d | e | Chamfer |
|---|---|---|---|---|---|---|
| 1.0 | 120 | 650 | 1000 | 400 | - | 135x135 |
| 1.5 | 120 | 650 | 1500 | 400 | - | 135x135 |
| 2.0 | 190 | 1000 | 2000 | 500 | - | 175x175 |
| 2.5 | 190 | 1500 | 2500 | 500 | 650 | 175x175 |
| 3.0 | 190 | 1500 | 3000 | 500 | 650 | 175x175 |
Milton Retaining Wall Units are manufactured from C50 concrete with 30mm nominal cover to reinforcement. They can be used in very severe exposure conditions as defined in BS 8110 Pt1 and severe exposure conditions as defined in BS 5400 Pt4. Stock units are suitable for loading from either side, with maximum loading from a level fill with a density of 19kNm³ and 10kN/m² live load surcharge or sloped up at max. 30° to an equivalent height to the wall. A qualified engineer should check the foundation and wall stability.