| Nominal Diameter (mm) | Actual Internal Diameter (mm) | Wall Thickness (mm) | Manhole Dept (mm) | Soakaways | Approx Weight / metre(kg) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 250 | 500 | 750 | 1000 | 500 | 750 | 1000 | |||||
| 900 | 914 | 70 | 490 | ||||||||
| 1050 | 1067 | 75 | 644 | ||||||||
| 1200 | 1219 | 90 | 852 | ||||||||
| 1350 | 1372 | 100 | - | 1118 | |||||||
| 1500 | 1524 | 100 | - | 1289 | |||||||
| 1800 | 1800 | 115 | - | 1695 | |||||||
| 2100 | 2100 | 125 | - | 2150 | |||||||
| 2400 | 2400 | 130 | - | 2553 | |||||||
| 2700 | 2700 | 140 | - | 3051 | |||||||
| 3000 | 3000 | 160 | - | 3820 | |||||||
| *4000 | 4000 | 200 | - | - | - | - | - | 6440 | |||
*4000 ring supplied in 2 halves of 3220kg/m depth.
All manholes from DN 1050 to DN 3000 are available with or without double steps
fitted.
| Nominal Depth | 900 | 1050 | 1200 | 1350 | 1500 | 1800 | 2100 | 2400 | 2700 | 300 |
|---|---|---|---|---|---|---|---|---|---|---|
| 500 | 6 | 6 | 7 | 8 | 9 | 12 | 11 | 13 | 15 | 17 |
| 750 | 8 | 10 | 12 | 12 | 14 | 16 | 23 | 27 | 30 | 34 |
| 1000 | 12 | 12 | 14 | 16 | 18 | 21 | 23 | 27 | 30 | 34 |
| Nominal Internal Dimeter | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 900 | 1050 | 1200 | 1350 | 1500 | 1800 | 2100 | 2400 | 2700 | 3000 | 4000 | |
| Litres/metre depth of chamber ring | 656 | 894 | 1167 | 1478 | 1824 | 2544 | 3464 | 4524 | 5725 | 7069 | 12566 |
1Litre = 0.001m³
Note: Joints for Soakaways should be made with cement mortor to ensure even
bedding of the units, but need not be watertight.
Important: The following table shows the size and position of access to comply with current Health and Safety Guidelines under the Confined Spaces Regulations 1997.
Summary of Requirements – Position and sizes of access
| Shaft/Chamber Size DN | Manhole less than 1.5m deep cover level to pipe soffit (mm) | Manhole greater than or equal to 1.5m deep cover level to pipe soffit (mm) |
|---|---|---|
| 900 | 600 x 600 central | 600 x 600 central |
| 1050 | 750 x 750 central | 600 x 600 central |
| 1200 | 750 x 600 eccentric | *750 x 600 eccentric |
| 1350 - 1500 | 1200 x 675 central | *750 x 600 eccentric |
| 1800 - 3000 | 1200 x 675 eccentric | *750 x 600 eccentric |
| 4000 | 900 x 600 |
*These sizes are to provide a 600 x 600 access when used in combination with one Type 1 and one or two Type 2 cover frame seating rings depending on depth to make up.
Other sizes access are available to order (Non BS Standard). DN 1350-1 for less than 1.5m depth. DN 1350-2 for greater than equal to 1.5m depth.
| Diameter (mm) | 900 | 1050 | 1200 | 1350-1 | 1350-2 | 1500 | 1800 | 2100 | 2400 | 2700 | 3000 | 4000 |
| Effective Depth (mm) | 125 | 125 | 125 | 150 | 125 | 150 | 150 | 165 | 165 | 180 | 200 | 275 |
| Nom Wt (kg) | 163 | 253 | 317 | 635 | 503 | 759 | 1113 | 1645 | 2163 | 2998 | 4164 | 9900* |
*DN 4000 supplied in two halves
Note: Reducing slabs reduce to a 1200 shaft. It is recommended that manholes of up to and including DN 1500mm continue to ground level and do not reduce in diameter but continue in the specified diameter for the whole construction.
| Diameter (mm) | 1800 | 2100 | 2400 | 2700 | 3000 | 4000 |
| Approx Wt (kg) | 1371 | 1934 | 2678 | 3543 | 4569 | 9420 |
*DN 4000 supplied in two halves, effective depth 275mm.
| Diameter (mm) | 1500 | 1800 | 2100 | 2400 | 2700 | 3000 | 4000 |
| Effective Depth (mm) | 150 | 150 | 165 | 165 | 180 | 200 | 165 |
| Nom Wt (kg) | 710 | 1060 | 1590 | 2110 | 2940 | 4100 | 4750 |
*Other access diameters are available to order.
All cover slabs, reducing slabs and landing slabs are Type 2 internal register except the DN 1350 cover slab with the 1200 x 675 access and the DN 4000 landing slab which is available as a half landing slab or a full slab supplied in two halves.
| Access Size (mm) | Thickness (mm) | Nom Wt (kg) | No Pallet | |
|---|---|---|---|---|
| Type 1 (eccentric) | 600 x 600 | 65 | 414 | 10 |
| Type 2 | 600 x 600 | 65 | 73 | 15 |
600 x 600 cover and frame to BS EN 124
Type 2 cover frame seating ring with 600 x 600 central access hole
Type 1 cover frame seating ring with 600 x 600 eccentric access hole positioned
to align with double steps
Four additional cover frame seating rings with 1200 x 675 access, 750 x 750, 750 x 600 and 675 x 675 access are available but not included in BS 5911-200
Tongue and groove joint provided can be sealed using a joint can be made using Miljoint butyl resin sealent available from Milton Pipes.