Milton Precast





Manhole and Soakaway Components

Sizes


Nominal Diameter (mm) Actual Internal Diameter (mm) Wall Thickness (mm) Manhole Dept (mm) Soakaways Approx Weight / metre(kg)
250 500 750 1000   500 750 1000
900 914 70   490
1050 1067 75   644
1200 1219 90   852
1350 1372 100 -   1118
1500 1524 100 -   1289
1800 1800 115 -   1695
2100 2100 125 -   2150
2400 2400 130 -   2553
2700 2700 140 -   3051
3000 3000 160 -   3820
*4000 4000 200 - -   - - - 6440

*4000 ring supplied in 2 halves of 3220kg/m depth.
All manholes from DN 1050 to DN 3000 are available with or without double steps fitted.



Perforation Detail for Soakaways


Nominal Depth 900 1050 1200 1350 1500 1800 2100 2400 2700 300
500 6 6 7 8 9 12 11 13 15 17
750 8 10 12 12 14 16 23 27 30 34
1000 12 12 14 16 18 21 23 27 30 34

View Soakaway Design



Chamber Ring Capacity


Nominal Internal Dimeter
  900 1050 1200 1350 1500 1800 2100 2400 2700 3000 4000
Litres/metre depth of chamber ring 656 894 1167 1478 1824 2544 3464 4524 5725 7069 12566

1Litre = 0.001m³
Note: Joints for Soakaways should be made with cement mortor to ensure even bedding of the units, but need not be watertight.



Cover and Reducing Slabs

Important: The following table shows the size and position of access to comply with current Health and Safety Guidelines under the Confined Spaces Regulations 1997.

Summary of Requirements – Position and sizes of access

Shaft/Chamber Size DN Manhole less than 1.5m deep cover level to pipe soffit (mm) Manhole greater than or equal to 1.5m deep cover level to pipe soffit (mm)
900 600 x 600 central 600 x 600 central
1050 750 x 750 central 600 x 600 central
1200 750 x 600 eccentric *750 x 600 eccentric
1350 - 1500 1200 x 675 central *750 x 600 eccentric
1800 - 3000 1200 x 675 eccentric *750 x 600 eccentric
4000   900 x 600

*These sizes are to provide a 600 x 600 access when used in combination with one Type 1 and one or two Type 2 cover frame seating rings depending on depth to make up.

Other sizes access are available to order (Non BS Standard). DN 1350-1 for less than 1.5m depth. DN 1350-2 for greater than equal to 1.5m depth.



Cover Slab


Diameter (mm) 900 1050 1200 1350-1 1350-2 1500 1800 2100 2400 2700 3000 4000
Effective Depth (mm) 125 125 125 150 125 150 150 165 165 180 200 275
Nom Wt (kg) 163 253 317 635 503 759 1113 1645 2163 2998 4164 9900*

*DN 4000 supplied in two halves



Reducing Slabs

(250mm deep no step for ladders or with double step fitted)

Note: Reducing slabs reduce to a 1200 shaft. It is recommended that manholes of up to and including DN 1500mm continue to ground level and do not reduce in diameter but continue in the specified diameter for the whole construction.

Diameter (mm) 1800 2100 2400 2700 3000 4000
Approx Wt (kg) 1371 1934 2678 3543 4569 9420

*DN 4000 supplied in two halves, effective depth 275mm.



Landing Slabs

(Access size 900mm diameter)
Diameter (mm) 1500 1800 2100 2400 2700 3000 4000
Effective Depth (mm) 150 150 165 165 180 200 165
Nom Wt (kg) 710 1060 1590 2110 2940 4100 4750

*Other access diameters are available to order.

All cover slabs, reducing slabs and landing slabs are Type 2 internal register except the DN 1350 cover slab with the 1200 x 675 access and the DN 4000 landing slab which is available as a half landing slab or a full slab supplied in two halves.



Cover Frame Seating Ring


Access Size (mm) Thickness (mm) Nom Wt (kg) No Pallet  
Type 1 (eccentric) 600 x 600 65 414 10
Type 2 600 x 600 65 73 15

600 x 600 cover and frame to BS EN 124
Type 2 cover frame seating ring with 600 x 600 central access hole
Type 1 cover frame seating ring with 600 x 600 eccentric access hole positioned to align with double steps

Four additional cover frame seating rings with 1200 x 675 access, 750 x 750, 750 x 600 and 675 x 675 access are available but not included in BS 5911-200



Jointing

Tongue and groove joint provided can be sealed using a joint can be made using Miljoint butyl resin sealent available from Milton Pipes.